APPLICATION CASE / 02

Low-pressure casting mould clamping

Close and clamp the mould, hold pressure, then release for opening and part removal.

China · 重庆志成机械有限公司 (Chongqing Zhicheng Machinery)

China · 重庆志成机械有限公司 (Chongqing Zhicheng Machinery)

Shanchuan hydraulic equipment photograph for construction reference, not the customer site
Shanchuan equipment · construction reference, not the customer site
Company-reported electricity saving
94.3%
Holding time
100–140 s
Recorded pressure
6.3 MPa
Production test
168 h

Original equipment and duty

The original pump ran continuously with a cooler. The hot casting environment recorded oil temperatures up to 68°C, leakage and monthly repairs. The production cycle was 180 s, including 100–140 s of holding.

Project duty: 100–140 s holding time; 6.3 MPa system pressure.

02 / ON-DEMAND POWER

Power for motion. Less energy during holding.

The retrofit retained the cylinders and valve block without changing the host machine, using a standard motor, PLC pressure feedback and an accumulator. The case scheme removed the original cooler and addressed the high-temperature, dusty environment separately.

  1. 01

    Build pressure

    Run the motor for clamping or pressing

  2. 02

    Hold pressure

    Stop the motor at the set pressure

  3. 03

    Recharge as needed

    Restart at the lower threshold

Test conditions and results

The project test covered 168 hours of continuous production at 34–41°C ambient temperature and 6.3 MPa system pressure, comparing consumption, oil temperature and faults before and after the retrofit.

What changed after the retrofit

Reported electricity saving 94.3%

Case record date: 2025-10-21

Oil temperature before65°C
Oil temperature after40°C

Test record and customer feedback

Test duration / ambient temperature / pressure: 168 h · 34–41°C · 6.3 MPa

Oil temperature (before→after): 65 → 40°C

Previously repaired monthly; six months without oil leakage after the retrofit.

Acceptance and a subsequent phased rollout to 12 units.

Customer feedback

Standard parts simplify repairs and reduce downtime losses from oil leakage.

Selection checks for a similar duty

Review ambient conditions, cooling and protection separately. This case pressure exceeds the 4.5 MPa SC-QT table rating and does not establish a direct replacement with those configurations.

Explore the solution for this duty →

Cooler removal, maintenance intervals and energy results relate only to this case record. Confirm heat balance, allowed pressure drop, leakage and duty rating for each new project.

Discuss a similar duty

ENERGY INTO VALUE

Less idle running. More value.

Make each holding phase count. Stop the motor after motion, then recharge when pressure reaches the set threshold, reducing energy use and heat from continuous idle running.

Save 75% or more in short-motion, long-hold applications. Turn reduced electricity use into lower running costs and get more value from every clamping cycle.

Annual electricity cost savingkWh avoided × electricity tariff
Review the savings potential of your machine →

Chongqing Zhicheng casting case study

The Zhicheng hydraulic retrofit concerns a casting fixture that closes, clamps, holds and releases. The reported pressure holding duty is 6.3 MPa, above the current catalogue rated pressure. Use this case to understand the cycle; it does not establish a direct replacement with a standard SC-QT configuration.